- Forfattere
- Magne E Runde
- Carl Ejnar Sølver
- antonio carvalho
- Manuel Cormenzana
- Hiroshi Furuta
- Wolfgang Grieshaber
- Antoni Hyrczak
- Dagmar Kopejtkova
- Johan Krone
- Mathias Kudoke
- Dirk Makareinis
- Jorge Matins
- Kresimir Mestrovic
- Ohno I
- Jan Østlund
- Kim Park
- J Patel
- Carsten Protze
- Joachim Schmid
- John Skog
- Bob Sweeney
- Francis Waite
- År
- 2012
- Type
- Forskningsrapport
Søk i SINTEF
- Forfattere
- Svein M. Hellesø
- Magne E Runde
- Knut Fandrem
- E. Petersson
- Kjell Halsan
- L. Carlshem
- J. Bartsch
- M. Jalonen
- År
- 2016
- Type
- Vitenskapelig kapittel
- Forfattere
- Svein M. Hellesø
- Magne E Runde
- K. Fandrem
- E. Petersson
- K. Å. Halsan
- L. Carlshem
- J. Bartsch
- M. Jalonen
- År
- 2016
- Type
- Konferanseforedrag
Loose particles and discharges inside the ducts of a gas-insulated substation (GIS) are considered hazardous to the insulation system. These irregularities or flaws can be detected by using acoustic sensors placed on the enclosure. An elementary review of sound propagation in a GIS together with...
- År
- 1990
- Type
- Vitenskapelig artikkel
Conventional 50/60 Hz induction heaters for aluminum billets have very large losses. By replacing the copper windings with windings of high-temperature superconducting (HTS) tapes, there is a substantial potential for efficiency improvements, especially if low AC loss HTS tapes become available. To...
- År
- 2003
- Type
- Vitenskapelig artikkel
In an induction heater for heating of aluminum billets, the main reason for using high-temperature superconducting (HTS) tapes instead of conventional copper conductors is to reduce the large power losses in the induction coil. In this work we present how to calculate the different loss...
- År
- 2003
- Type
- Vitenskapelig artikkel
Air has been considered a good alternative to SF6 as arc quenching medium for load break switchgear at medium voltage ratings. In this work, the air flow characteristics and influence from the electric arc have been studied for typical currents and over-pressures. The cooling air velocity is...
- År
- 2015
- Type
- Vitenskapelig artikkel
Failure frequencies for circuit breakers (CBs) (only single pressure ${rm SF}_{6}$), disconnectors and earthing switches, instrument transformers, and gas-insulated switchgear (GIS) have been determined through a comprehensive worldwide utility survey. For CBs and GIS, where comparable results from...
- Forfattere
- Magne E Runde
- År
- 2013
- Type
- Vitenskapelig artikkel
One type test requirement for medium voltage load break switches is to interrupt 100 consecutive "mainly active loads". A puffer-type switch with axial-blown arc has been tested according to the 630 A/24 kV ratings. The nozzle and contact wear were measured regularly to investigate design...
- År
- 2017
- Type
- Vitenskapelig artikkel
- Forfattere
- Kristbjörg Edda Jónsdóttir
- Andreas Ugelvik Misund
- Leif Magne Sunde
- Merete Bjørgan Schrøder
- Zsolt Volent
- År
- 2022
- Type
- Populærvitenskapelig artikkel
Permaskjørt – Resultater og erfaringer fra bruk
- Forfattere
- Andreas Myskja Lien
- Kevin Frank
- Zsolt Volent
- Per Rundtop
- Lars Christian Gansel
- Jens Birkevold
- Per Christian Endresen
- Leif Magne Sunde
- År
- 2014
- Type
- Konferanseforedrag
Offshore vindmøller neste?
...man designer og bruker elkrafttekniske komponenter, sier SINTEF-forskerne Magne Runde og Niklas Magnussen. – I et lengre tidsperspektiv kan høytemperatur superledere derfor få stor betydning og en bred anvendelse, sier Runde og Magnusson. Havmøller neste? – Hvor er det neste stedet verden kan få glede...
Cryogenic design of the ALUHEAT project
...is presented in detail. The induction heater consists of two magnets in separate cryostats and the billet to be heated is rotated between the cryostats. Short distance between the magnet and cryostat wall, large forces between the magnets, and the need to rotate the billet create application specific...
- Forfattere
- Magne E Runde
- År
- 2008
- Type
- Vitenskapelig kapittel
A 420 kV gapped-core five-legged variable shunt reactor is modeled in the frequency range 5 Hz-10 MHz based on frequency sweep measurements and curve fitting. Comparison with time domain measurements at reduced voltage shows that the model can accurately predict the transient behavior of the shunt...
- År
- 2015
- Type
- Vitenskapelig artikkel
Empirical Relationships between Air-Load Break Switch Parameters and Interrupting Performance
A simple gas blow switch consisting of an axisymmetric tulip/pin contact and a cylindrical polytetrafluoroethylene (PTFE) nozzle has been used for empirical studies of medium voltage load current interruption in air. Only the thermal phase of the interruption is considered. Based on the results of...
- År
- 2016
- Type
- Vitenskapelig artikkel
- Forfattere
- Andreas Myskja Lien
- Lars Helge Stien
- Kevin Frank
- Zsolt Volent
- Per Rundtop
- Lars Gansel
- Jens Birkevold
- Per Christian Endresen
- Leif Magne Sunde
- År
- 2015
- Type
- Konferanseforedrag
Sixteen different commercial bolted connectors for 50 and 240 mm2 stranded aluminum cable conductors have been examined in order to identify and clarify the correlations between the quality of a connector and its design characteristics, material usage, assembly procedures, bolt numbers and...
- År
- 2008
- Type
- Vitenskapelig artikkel
Near an electric arc some polymers, known as ablation materials, change the properties of the arcing medium in a beneficial manner. The interruption capability for current interruption improves by increasing the pressure and the heat dissipation from the arc. The present paper studies medium voltage...
- År
- 2014
- Type
- Vitenskapelig kapittel
The MgB2 superconductor is an attractive choice for many high-current DC applications, particularly for its low cost compared to e.g. YBCO, and the higher operating temperature than the low-temperature superconductors. To extend the operating range to include also AC applications, the AC losses need...
- År
- 2012
- Type
- Vitenskapelig artikkel
The current interrupting capability of a load break switch (LBS) depends on many design parameters, such as contact and nozzle geometry, contact movement, and gas flow. For developing more compact gas blow LBSs for air, it is necessary to find design recommendations where each parameter is...
- År
- 2014
- Type
- Vitenskapelig artikkel