Til hovedinnhold

Svein Magne Hellesø

Forsker

Svein Magne Hellesø

Forsker

Svein Magne Hellesø
Telefon: 482 32 345
E-post:
Avdeling: Elkraftteknologi
Kontorsted: Trondheim

Publikasjoner og ansvarsområder

Publikasjon
https://www.sintef.no/publikasjoner/publikasjon/1918843/

We report on the testing of a 1 m long and 0.5 m wide racetrack coil wound from 4.5 km of MgB2 tape-shaped superconductors with a copper strip soldered to the nickel matrix. The cross-section of the coil corresponds to what is needed for the field windings of a 10 MW direct drive wind turbine...

Forfattere Niklas Magnusson Svein Magne Hellesø R. Mikkonen A.B. Abrahamsen Magne E Runde Gunnar Berg-Karlsen Arne Nysveen
År 2021
Type Vitenskapelig artikkel
Publikasjon
https://www.sintef.no/publikasjoner/publikasjon/1915878/

Thermal expansion and contraction of the impregnation oil (the “mass”) in mass-impregnated non-draining HVDC cables cause the internal pressure to vary greatly during load changes. Pressure drops after load turn-off is a concern since formation of shrinkage cavities may reduce the dielectric...

År 2021
Type Vitenskapelig artikkel
Publikasjon
https://www.sintef.no/publikasjoner/publikasjon/1573249/

Field windings made of MgB2 wires or tapes are considered for their potential to reduce volume, weight and cost of large offshore wind turbine generators. To gain experience of how to use this relatively new material in full-scale generators, tests of different winding methodologies and techniques...

Forfattere Niklas Magnusson Jan Christian Eliassen Asger Bech Abrahamsen Svein Magne Hellesø Magne E Runde Arne Nysveen Lars-Erik Moslått Jarle Bjerkli Patrick King
År 2018
Type Vitenskapelig artikkel
Publikasjon
https://www.sintef.no/publikasjoner/publikasjon/1492772/

In this paper we present experimental and numerical studies of the electrohydrodynamic stretching of a sub-millimetre-sized salt water drop, immersed in oil with added non-ionic surfactant, and subjected to a suddenly applied electric field of magnitude approaching 1 kV/mm. By varying the drop size...

Forfattere Åsmund Ervik Torstein Eidsnes Penne Svein Magne Hellesø Svend Tollak Munkejord Bernhard Müller
År 2017
Type Vitenskapelig artikkel
Publikasjon
https://www.sintef.no/publikasjoner/publikasjon/1477545/

Infrastructures such as road crossings, are often limiting the ampacity of a cable link due to poor thermal properties. In order to fully utilize the true loading capacity of the cable, thermal modelling with correct input parameters should be applied. In this work, a full scale artificial road...

År 2017
Type Vitenskapelig Kapittel/Artikkel/Konferanseartikkel
Publikasjon
https://www.sintef.no/publikasjoner/publikasjon/1258256/

This paper presents results from numerical calculations of water ingress in a wet designed subsea XLPE cable equipped with a two-layered outer sheath, and results from water tree ageing at different relative humidity (RH) levels in an XLPE cable core. The results from the water tree ageing show...

Forfattere Torbjørn Andersen Ve Sverre Hvidsten Jorunn Hølto Svein Magne Hellesø Knut Magne Furuheim Hanna Hedström
År 2016
Type Vitenskapelig Kapittel/Artikkel/Konferanseartikkel
Publikasjon
https://www.sintef.no/publikasjoner/publikasjon/1329602/

Ved å bruke dobbel loop, så øker stivheten til omføringsloopen slik at egenfrekvensen øker og resonans med vinden unngås/reduseres. Dette gir igjen redusert utsving i omføringsloopen. Simuleringene viser at antall avstandsstykker har stor betydning for å øke stivheten, og dermed redusere utsvinget...

Forfattere Svein Magne Hellesø Steinar Refsnæs Steinar Strømdahl
År 2016
Type Rapport