To facilitate operation of power electronics for subsea operation at ambient pressure components have to be submerged in a liquid. Equipment and schemes for testing of long term properties have been developed. Several techniques were used to investigate compatibility between a silicone gel and various insulation fluids. Equipment for electric endurance testing of power electronic components at dc stress under controlled temperature and humidity was developed. Performance of high voltage diodes covered with various insulation liquids, coatings and gel covering were studied.
Les publikasjonen

Kategori

Vitenskapelig kapittel

Språk

Engelsk

Institusjon(er)

  • SINTEF Industri / Bioteknologi og nanomedisin
  • SINTEF Energi AS / Elkraftteknologi
  • SINTEF Energi AS / Energisystemer

År

2016

Forlag

IEEE (Institute of Electrical and Electronics Engineers)

Bok

Proceedings of the 2016 IEEE International Conference on Dielectrics, 3-7 July 2016, University of Montpellier, France : ICD 2016

ISBN

9781509028047

Vis denne publikasjonen hos Nasjonalt Vitenarkiv