Til hovedinnhold
Norsk English

Reliability and validity of the international physical activity questionnaire in the Nord-Trondelag health study (HUNT) population of men.

Sammendrag

BackgroundThere is no standardized method for the assessment of physical activity (PA). Therefore it is important to investigate the validity and comparability of different measures. The International Physical Activity Questionnaire (IPAQ) has been developed as an instrument for cross-national assessment of PA and has been validated in 12 countries. These instruments have acceptable measurement properties for monitoring population levels of PA among 18–65 year-old adults in diverse settings. However, there are some concerns that IPAQ may over-report PA. The purpose of this study is to evaluate the reliability and validity of IPAQ, short version, last 7-days in the Nord-Trøndelag Health Study (HUNT) population of men. MethodsThe questionnaire was administered twice to a random sample of 108 men aged 20–39 and validity by comparing results with VO2max and ActiReg, an instrument that measures PA and energy expenditure (EE). ActiReg discriminates between the body positions: stand, sit, bend forward and lie and also registers if there is motion or not in each of them or both. ResultsOur results for reliability of the IPAQ short version were good for vigorous and fair for moderate activities. Intraclass correlations ranged from a low of 0.30 for moderate activity hours, to a high of 0.80 for sitting hours. Concerning validity, our results suggest that total IPAQ vigorous PA was a moderately good measure of vigorous activity, having moderately strong, significant correlations with VO2max, r = 0.41 (p ≤ 0.01), but correlated not with metabolic equivalent (METs) values of 6 or more measured with ActiReg. Only total IPAQ walking was fair correlated with METs 1–3 and METs 3–6, respectively r = -0.27 and 0.26 (p ≤ 0.05). The index for IPAQ sitting hours per week was moderate correlated with METs values of 1–3 and negatively correlated with METs values of 3–6. Classification of PA in three levels (low, moderate and high) correlated also most strongly with VO2max (0.31 p ≤ 0.01) a

Kategori

Vitenskapelig artikkel

Språk

Engelsk

Forfatter(e)

  • Brit Nanna Kurtze
  • Vegar Rangul
  • Bo-Egil Hustvedt

Institusjon(er)

  • SINTEF Digital / Helse

År

2008

Publisert i

BMC Medical Research Methodology

ISSN

1471-2288

Forlag

BioMed Central (BMC)

Årgang

8

Vis denne publikasjonen hos Cristin