Publikasjon
https://www.sintef.no/publikasjoner/publikasjon/?pubid=CRIStin+1627875

An experimental two-phase flow campaign with a viscous oil (100 cP) was conducted in the Large Scale 8" loop at the SINTEF Multiphase Flow Laboratory. The loop consisted of three main test sections, with pipe inclinations 0, 0.5 and 90 degrees, and with approximate lengths of 380 m, 380 m and 5...

Forfattere Kjølaas Jørn Smith Ivar Eskerud Brekken Christian
År 2018
Type Del av bok/rapport
Publikasjon
https://www.sintef.no/publikasjoner/publikasjon/?pubid=CRIStin+1627835

An experimental two-phase flow campaign with a viscous oil (100 cP) was conducted in the Large Scale 8" loop at the SINTEF Multiphase Flow Laboratory. The loop consisted of three main test sections, with pipe inclinations 0, 0.5 and 90 degrees, and with approximate lengths of 380 m, 380 m and 5...

Forfattere Kjølaas Jørn Smith Ivar Eskerud Brekken Christian
År 2018
Type Konferansebidrag og faglig presentasjon
Publikasjon
https://www.sintef.no/publikasjoner/publikasjon/?pubid=CRIStin+1487339

An experimental study of vertical two-phase flow was conducted at the SINTEF Multiphase Laboratory using a 51 meter long 4" pipe at system pressures of 45 and 70 bara. This campaign was conducted as part of a project aimed at improving the physical models in LedaFlow for near-vertical pipes, an...

År 2017
Type Del av bok/rapport
Publikasjon
https://www.sintef.no/publikasjoner/publikasjon/?pubid=CRIStin+1487334

At high gas rates, even small amounts of liquid can have a significant impact on the pressure drop, and this is important to model accurately when designing wet gas transport systems. In order to gain an improved understanding of this matter, several sets of two- and three-phase experiments in low l...

Forfattere Kjølaas Jørn Unander Tor Erling Wolden Marita Shmueli Alvarado Andrea Holm Henning
År 2017
Type Del av bok/rapport
Publikasjon
https://www.sintef.no/publikasjoner/publikasjon/?pubid=CRIStin+1394133

An experimental study of vertical two-phase flow was conducted at the SINTEF Multiphase Laboratory using a 55 meter long 4" pipe at system pressures of 20, 45 and 70 bara. One of the main objectives of the campaign was to identify regions with multiple solutions, where two flow regimes can coex...

År 2016
Type Del av bok/rapport