To main content

Marion O Farrell

Research Manager

Marion O Farrell

Research Manager

Marion O Farrell
Phone: 920 27 654
Department: Smart Sensor Systems
Office: Oslo

Publications and responsibilities

Publication
https://www.sintef.no/en/publications/publication/?pubid=CRIStin+1697437

The field of applied spectroscopy is strongly dominated by publications presenting proof-of-concepts, lab set-ups, and demonstrations. In contrast, the corresponding number of commercial successes of inline spectroscopy is surprisingly lower. This article discusses inline spectroscopy from an instru...

Year 2019
Type Conference lecture and academic presentation
Publication
https://www.sintef.no/en/publications/publication/?pubid=CRIStin+1600099

The field of applied spectroscopy is strongly dominated by publications presenting proof-of-concepts, lab set-ups, and demonstrations. In contrast, the corresponding number of commercial successes of inline spectroscopy is surprisingly lower. This article discusses inline spectroscopy from an instru...

Year 2018
Type Journal publication
Publication
https://www.sintef.no/en/publications/publication/?pubid=CRIStin+1567223

In this article the development of a newly designed Time-of-Flight (ToF) image sensor for underwater applications is described. The sensor is developed as part of the project UTOFIA (underwater time-of-flight image acquisition) funded by the EU within the Horizon 2020 framework. This project aims to...

Authors Driewer Adrian Abrasimov Igor Alexander Jonathan Benger Marc O'Farrell Marion Haugholt Karl Henrik Softley Chris Thielemann Jens T Thorstensen Jostein Bruun Yates Chris
Year 2017
Type Journal publication
Publication
https://www.sintef.no/en/publications/publication/?pubid=CRIStin+1463818

The ability of NMR to predict purge from vacuum-packed pork that was stored for 9 days was investigated. T2 relaxation was measured at 24 h post mortem (p.m.) and again after 9 days of chilled storage. NMR measurements from day 1 p.m. were limited in predicting day-9 purge (|r| = 0.37–0.52). The roo...

Authors Zhu Han O'Farrell Marion Hansen Eddy Walther Andersen Petter Vejle Berg Per Egelandsdal Bjørg Tordis
Year 2017
Type Journal publication
Publication
https://www.sintef.no/en/publications/publication/?pubid=CRIStin+1303047

The potential of using NMR as a reference method for WHC measurement in porcine longissimus dorsi was investigated. The accuracy of NMR when measuring small water changes was assessed in a model system and in muscles. Visible/near infrared (Vis/NIR) and X-ray were used as potential online spectrosco...

Authors Zhu Han O'Farrell Marion Bouquet Grégory Lunde Kathrine Egelandsdal Bjørg Alvseike Ole Berg Per Gjerlaug-Enger Eli Hansen Eddy Walther
Year 2016
Type Journal publication
Publication
https://www.sintef.no/en/publications/publication/?pubid=CRIStin+1002744

A low-cost Fourier transform infrared (FTIR) instrument was developed where the traditional He–Ne reference laser was replaced by a low-cost linear encoder. An RMS sampling error of less than 20 nm was achieved by oversampling both the interferogram and the encoder signal and then resampling the int...

Authors Haugholt Karl Henrik Lacolle Matthieu Jean P O'Farrell Marion Honne Atle Bakke Kari Anne Hestnes Lundon Aina
Year 2013
Type Journal publication