- Authors
- Magne E Runde
- Carl Ejnar Sølver
- antonio carvalho
- Manuel Cormenzana
- Hiroshi Furuta
- Wolfgang Grieshaber
- Antoni Hyrczak
- Dagmar Kopejtkova
- Johan Krone
- Mathias Kudoke
- Dirk Makareinis
- Jorge Matins
- Kresimir Mestrovic
- Ohno I
- Jan Østlund
- Kim Park
- J Patel
- Carsten Protze
- Joachim Schmid
- John Skog
- Bob Sweeney
- Francis Waite
- Year
- 2012
- Type
- Research report
SINTEF search
- Authors
- Svein M. Hellesø
- Magne E Runde
- Knut Fandrem
- E. Petersson
- Kjell Halsan
- L. Carlshem
- J. Bartsch
- M. Jalonen
- Year
- 2016
- Type
- Academic chapter
- Authors
- Svein M. Hellesø
- Magne E Runde
- K. Fandrem
- E. Petersson
- K. Å. Halsan
- L. Carlshem
- J. Bartsch
- M. Jalonen
- Year
- 2016
- Type
- Conference lecture
Loose particles and discharges inside the ducts of a gas-insulated substation (GIS) are considered hazardous to the insulation system. These irregularities or flaws can be detected by using acoustic sensors placed on the enclosure. An elementary review of sound propagation in a GIS together with...
- Year
- 1990
- Type
- Academic article
Conventional 50/60 Hz induction heaters for aluminum billets have very large losses. By replacing the copper windings with windings of high-temperature superconducting (HTS) tapes, there is a substantial potential for efficiency improvements, especially if low AC loss HTS tapes become available. To...
- Year
- 2003
- Type
- Academic article
In an induction heater for heating of aluminum billets, the main reason for using high-temperature superconducting (HTS) tapes instead of conventional copper conductors is to reduce the large power losses in the induction coil. In this work we present how to calculate the different loss...
- Year
- 2003
- Type
- Academic article
Air has been considered a good alternative to SF6 as arc quenching medium for load break switchgear at medium voltage ratings. In this work, the air flow characteristics and influence from the electric arc have been studied for typical currents and over-pressures. The cooling air velocity is...
- Year
- 2015
- Type
- Academic article
Failure frequencies for circuit breakers (CBs) (only single pressure ${rm SF}_{6}$), disconnectors and earthing switches, instrument transformers, and gas-insulated switchgear (GIS) have been determined through a comprehensive worldwide utility survey. For CBs and GIS, where comparable results from...
- Authors
- Magne E Runde
- Year
- 2013
- Type
- Academic article
One type test requirement for medium voltage load break switches is to interrupt 100 consecutive "mainly active loads". A puffer-type switch with axial-blown arc has been tested according to the 630 A/24 kV ratings. The nozzle and contact wear were measured regularly to investigate design...
- Year
- 2017
- Type
- Academic article
- Authors
- Kristbjörg Edda Jónsdóttir
- Andreas Ugelvik Misund
- Leif Magne Sunde
- Merete Bjørgan Schrøder
- Zsolt Volent
- Year
- 2022
- Type
- Popular science article
Permaskjørt – Resultater og erfaringer fra bruk
- Authors
- Andreas Myskja Lien
- Kevin Frank
- Zsolt Volent
- Per Rundtop
- Lars Christian Gansel
- Jens Birkevold
- Per Christian Endresen
- Leif Magne Sunde
- Year
- 2014
- Type
- Conference lecture
Cryogenic design of the ALUHEAT project
...is presented in detail. The induction heater consists of two magnets in separate cryostats and the billet to be heated is rotated between the cryostats. Short distance between the magnet and cryostat wall, large forces between the magnets, and the need to rotate the billet create application specific...
- Authors
- Magne E Runde
- Year
- 2008
- Type
- Academic chapter
Sixteen different commercial bolted connectors for 50 and 240 mm2 stranded aluminum cable conductors have been examined in order to identify and clarify the correlations between the quality of a connector and its design characteristics, material usage, assembly procedures, bolt numbers and...
- Year
- 2008
- Type
- Academic article
Near an electric arc some polymers, known as ablation materials, change the properties of the arcing medium in a beneficial manner. The interruption capability for current interruption improves by increasing the pressure and the heat dissipation from the arc. The present paper studies medium voltage...
- Year
- 2014
- Type
- Academic chapter
The MgB2 superconductor is an attractive choice for many high-current DC applications, particularly for its low cost compared to e.g. YBCO, and the higher operating temperature than the low-temperature superconductors. To extend the operating range to include also AC applications, the AC losses need...
- Year
- 2012
- Type
- Academic article
A 420 kV gapped-core five-legged variable shunt reactor is modeled in the frequency range 5 Hz-10 MHz based on frequency sweep measurements and curve fitting. Comparison with time domain measurements at reduced voltage shows that the model can accurately predict the transient behavior of the shunt...
- Year
- 2015
- Type
- Academic article
Empirical Relationships between Air-Load Break Switch Parameters and Interrupting Performance
A simple gas blow switch consisting of an axisymmetric tulip/pin contact and a cylindrical polytetrafluoroethylene (PTFE) nozzle has been used for empirical studies of medium voltage load current interruption in air. Only the thermal phase of the interruption is considered. Based on the results of...
- Year
- 2016
- Type
- Academic article
- Authors
- Andreas Myskja Lien
- Lars Helge Stien
- Kevin Frank
- Zsolt Volent
- Per Rundtop
- Lars Gansel
- Jens Birkevold
- Per Christian Endresen
- Leif Magne Sunde
- Year
- 2015
- Type
- Conference lecture
The current interrupting capability of a load break switch (LBS) depends on many design parameters, such as contact and nozzle geometry, contact movement, and gas flow. For developing more compact gas blow LBSs for air, it is necessary to find design recommendations where each parameter is...
- Year
- 2014
- Type
- Academic article
Replacing SF6 with air as the arc quenching medium in switching equipment is favorable from an environmental point of view, but may be technically difficult for compact devices. Medium-voltage load break switches have modest current and voltage ratings, typically 630 A/24 kV, and are thus expected...
- Year
- 2015
- Type
- Academic article