Model complexity of heat pump systems to investigate the building energy flexibility and guidelines for model implementation

Abstract

Building performance simulation (BPS) is a powerful tool for engineers working in building design and heating,
ventilation and air-conditioning. Many case studies using BPS investigate the potential of demand response (DR)
measures with heat pumps. However, the models are often simplified for the components of the heat pump
system (i.e. heat pump, electric auxiliary heater and storage tank) and for their interactions. These simplifications
may lead to significant differences in terms of DR performance so that more comprehensive models for a
heat pump system may be necessary. The contribution of this work is twofold. Firstly, this work investigates the
influence of the modeling complexity of the heat pump control on different key performance indicators for the
energy efficiency, the DR potential and the heat pump operation. To this end, the performance of six different
heat pump controls is compared. Secondly, it describes the implementation of a comprehensive control for a heat
pump system in BPS tools. This control is not often documented in the BPS literature and is error-prone. Generic
pseudo-codes are provided, whereas IDA ICE is taken as an example in the case study. A predictive rule-based
control is implemented to study price-based DR of residential heating. It is shown that a realistic operation of the
heat pump system can be achieved using the proposed modeling approach. The results prove that the modeling
complexity of the system control has a significant impact on the performance indicators, meaning that this aspect
should not be overlooked. For some performance indicators, e.g. the annual energy use for heating and average
water tank temperature, it is shown that a proportional (P-) and proportional-integral (PI-) control can lead to
similar results. If the heat pump operation is investigated in detail and a short-time resolution is required, the
difference between P- and PI-controls and their tuning is important. As long as the heat pump operation and
electrical power at short timescales are not of importance, the choice of controller (P or PI) is not crucial.
However, the use of P-control significantly simplifies the modeling work compared to PI-control. If DR is performed
for domestic hot water, it is also demonstrated that the prioritization of domestic hot water heating can
indirectly influence the operation of auxiliary heaters for space-heating, significantly increasing the use of
electricity. However, the electricity use is only slightly increased if DR control is only used for space heating.
Read publication

Category

Academic article

Client

  • Research Council of Norway (RCN) / 257660

Language

English

Author(s)

Affiliation

  • Norwegian University of Science and Technology

Year

2019

Published in

Applied Energy

ISSN

0306-2619

Publisher

Elsevier

Volume

255

View this publication at Cristin