Abstract
In the period between 2016 to 2021 the Research Council of Norway (RCN) funded a research project at NTNU entitled Wood frame solutions for free space design in urban buildings (Woodsol). The main goal of the Woodsol project was to develop industrialized structural solutions based on rigid wooden frames for use in urban buildings between five to ten stories, with an open architecture as one of several selling points. The project was coordinated at NTNU at the Department of Structural Engineering, and the main research partners were SINTEF Community and the Department of Civil and Transport Engineering at NTNU. Eight industrial partners aided the direction and relevance of the research activities, which were related to moment resisting connections and frames, flooring systems, acoustics, and prototyping. Three PhD degrees were awarded during the research project, and numerous master students at NTNU have made their thesis on topics connected to the Woodsol research activities. As part of the dissemination of the research, the RCN invited the project to produce a reference work explaining the application and use of the Woodsol building system, and the present document is intended to be a response to that invitation.
The point of departure is a property of the material. In comparison to concrete or steel buildings, timber buildings are lightweight and have moderate stiffness. The lightness can be exploited to increase the speed of assembly on site and to reduce the cost of foundations, but it also makes timber buildings prone to wind-induced loading, which can result in excessive deformations and in movements and vibrations that are uncomfortable under service load. At present, the two main structural systems for multi-storey timber buildings are based either on diaphragm walls, such as shear walls in cross-laminated timber, or on trusswork members stabilised by diagonals. Woodsol is also a trusswork system, but the lateral stability is instead produced by a rotationally stiffened joint between post and beam. The beam is integrated in the floor element and connected to a continuous glulam column through a moment-resisting connector developed particularly in the Woodsol project. The system is characterised by its structural simplicity: a regular grid, and structural components that repeat, as explained in chapter 2.
The benefit of combining moment-resisting connections with a closed hollow-section stressed skin floor element is twofold. On one hand, the performance of the floor elements under service load is improved and longer spans can be achieved. On the other hand, moment-resisting frames with semi-rigid connections contribute to the lateral stiffness in one of the two horizontal directions of the building and therefore reduce the need for bracing elements. The longer spans and the frames together allow for more open space and flexible architecture. All structural components are industrialized and highly prefabricated, the connector included: one part is anchored to the edge joists of the floor element and the other to the column, both may be pre-installed in the factory, and only mating and fastening of the two parts is required on site.
The floor element is the horizontal member of this system, and chapter 3 describes it in detail. Its primary structure is a closed hollow section formed by two flanges of laminated veneer lumber glued to a core frame of glulam edge joists, end beams and field joists, with the cavities filled to a distributed mass in the order of 100 kg/m2 for acoustic performance. The element is flexible with respect to support conditions and lateral connectivity: three support conditions are available longitudinally, of which the moment-resisting connector is one, and two transversally, while in-fill floor completion elements provide the required longitudinal continuation and three transverse interconnections are available. All methods of lateral continuation influence the dynamic response of the flooring system and should be selected with caution. Outfitting, that is overlay, internal mass and ceiling system, is treated together with floor serviceability, which is assessed both by current Norwegian practice and by the approach proposed for the second generation of Eurocode 5. The pre-calculated elements presented were optimised with respect to cost with serviceability treated as a constraint, and they require detailed design calculation once the loads, outfitting and adaptions of the specific project are known.
Chapter 4 turns to the vertical system and to the connector itself. For buildings of this height the governing challenge is not strength but serviceability: wind-induced lateral displacements, inter-storey drifts and accelerations at the top floor. Because the relations given in EN 1991-1-4 and EN 1998-1 do not describe moment-resisting timber frames well, closed-form expressions for preliminary design are provided for roof displacement, inter-storey drift, fundamental eigenfrequency, mode shape and peak acceleration, derived from parametric finite element analyses of planar frames. Frames of up to eight to ten storeys are feasible, whereas slender buildings of only one or two bays cannot fulfil the requirements; increased mass and greater building width are the effective remedies. The connector is then described part by part, that is screws, brackets, transfer plate, shims and pretensioned bolts, followed by the geometry and the procedures for installation and for pretensioning the slip-resistant connection. Its design idea is to make a very stiff connection without brittle failure modes, by letting the frictional resistance in the slip-resistant point connections have lower resistance, and give larger deformation, than all other failure modes.
Chapter 5 starts with a brief introduction of the acoustic concepts and gives an insight in the major challenges relevant for the Woodsol building system, and then presents a summary of the acoustic properties of the Woodsol floor elements. Measurement data describing solutions for a broad range of applications are given along with analytical relations for preliminary dimensioning of the components. In depth information is provided for the low frequency behaviour of the floor elements and the effect of the boundary conditions, and the chapter closes by introducing the topic of flanking transmission and a pragmatical way of tackling these aspects within the building system.
Structural design for fire safety, treated in chapter 6, includes considerations of the behaviour of timber structures during fire exposure, like the combustibility of the structure, protection of junctions and the timbers contribution to the fire load leading to increased fire severity. Columns, beams and CLT-walls must be designed to sustain sufficient strength and stiffness for the required fire resistance time. Different methods can be used, including the use of fire protective cladding or the inclusion of a safety margin when calculating the required dimensions. Sufficient charring protection is also an important issue for base floor elements and for the moment-resisting connectors.
In chapter 7, an environmental assessment has been carried out to estimate embodied emissions from materials in the building, for the construction phase only. The assessment is a first iteration based on generic emission factors for different materials. The results indicate an equal contribution from the primary structural system in wood and from the remaining materials and components for basic building performance, both with approximately 44 % of total embodied emissions from the construction phase, while the remaining emissions are associated with concrete for structural purposes in the basement.
In chapter 8, concerns about end of life is discussed. Whether a building system can be dismantled is decided in practice by what the operation costs, and the Woodsol system is comparatively inexpensive to dismantle. The threaded rods embedded in the glulam are permanent, but the bolted interface between the metallic coupling parts is fully demountable, and no adhesive is used in any of the on-site joints. The floor elements can therefore be separated from the columns without damaging the structural timber; they leave the building with their coupling geometry intact and can be mounted on new glulam columns in a new building, where the moment-resisting action is re-established by tightening the bolts of the friction connection to the specified torque. The columns may be reused with the rods left in place, or the rods extracted at the cost of local damage of small structural consequence.
Taken together, the chapters describe a building system whose central choice, placing the stabilising function in the joint rather than in walls and cores, propagates through every part of the work. It is what permits the long floor spans and the open plan that motivated the project; it is what sets the serviceability criteria that govern the design of the frames; it is what the acoustic and fire design must accommodate; and it is what leaves the completed building 8
adaptable in use and inexpensive to take apart. The Woodsol system thus provides an extended, adaptable service life in the initial building, followed by economical recovery of its main components for use in a subsequent building.