To main content

Time to breakdown studies for liquids of different physico-chemical nature

Time to breakdown studies for liquids of different physico-chemical nature

Category
Part of a book/report
Abstract
An automated setup for testing dielectric performance of liquids in a small point-to-plane gap is presented. It provides step voltages with rise times around 30 ns, with amplitudes up to 90 kV. Breakdown studies of thirteen different liquids were conducted with a gap distance of 4 mm in a test cell containing 20 ml liquid. The liquids were circulated and filtered after each breakdown to remove carbonized particles and relax space charges. Time to breakdown versus applied voltage was recorded, and for streamers that stopped mid gap, shadow graphic images of streamer structures were taken. Multivariate correlation studies between streamer properties and physio-chemical parameters of liquids were made, indicating relevance of liquid evaporation and electronic states of molecules.
Client
  • Norges forskningsråd / 228850
Language
English
Author(s)
Affiliation
  • SINTEF Energy Research / Elkraftteknologi
  • Sweden
Year
2017
Published in
Proceedings of IEEE International Conference on Dielectric Liquids
ISSN
2153-3725
Publisher
IEEE conference proceedings
Book
2017 IEEE 19th International Conference on Dielectric Liquids - ICDL
Booklet
2017
ISBN
978-1-5090-4877-9