Abstract
Freezing dilation clear function of DS/DCS: DScrit ≈ 0.80 in ASR affected concrete from Voll
•
Hydraulic pressure induced expansion observed at DS = 0.86 and 0.90, i.e. frost damage mainly occurs during temperature drop, and less at constant low temperature.
•
At DS = 0.86 «some growth of bodies of ice» observed
•
All concrete specimens are presumably non-air entrained, hence pre-existing cracks will accelerate damage (Zhou, Cohen & Dolch ACI 1994)
•
The effect of pre-existing cracks by ASR in frost-degradation of Non-Air entrained concrete:
–
Deterioration as surface scaling inside water filled cracks – high DS - (photo slides 13-14), presumably by HP due to high DS
–
If crack is not water filled (vertical part of structure, crack to wide to suck water) and DS < DScrit then crack widening over time is due to ASR (due to expanding core concrete?)