AC Corrosion Tests on Materials for Electrically Heated Flowlines

Sammendrag

This paper presents results from AC corrosion tests on cathodically protected steel flowlines. An important factor, which has an increased focus in the industry, is to understand AC corrosion and how it can be mitigated. Tests have been carried out at 100 and 200 Hz, where no current transfer design limits exist, as well as at 50 Hz. The results show that the corrosion rate is independent of transfer current density (0-400 A/m2) and power frequency (0-200 Hz) on steel. On the anodes, the corrosion rate increases as a function of transfer current density (0-80 A/m2) at 50 Hz. However, the correlation is less prominent at higher frequencies (100-200 Hz). Copyright © 2018 by the International Society of Offshore and Polar Engineers (ISOPE)
Les publikasjonen

Kategori

Vitenskapelig Kapittel/Artikkel/Konferanseartikkel

Oppdragsgiver

  • Research Council of Norway (RCN) / 256507

Språk

Engelsk

Forfatter(e)

Institusjon(er)

  • SINTEF Energi AS / Elkraftteknologi
  • Nexans Norway AS

År

2018

Forlag

International Society of Offshore & Polar Engineers

Bok

The Proceedings of The Twenty-eighth (2018) International OCEAN AND POLAR ENGINEERING CONFERENCE, ISOPE 2018

Hefte nr.

2018

ISBN

978-1-880653-87-6

Side(r)

265 - 269

Vis denne publikasjonen hos Cristin