The Influence of Plastic Strain on the Effective Hydrogen Diffusion Coefficient and Trapping in Base Metal and Weld Simulated Heat Affected Zone of an X70 Pipeline Steel

Sammendrag

Electrochemical hydrogen permeation measurements have been performed on pre-strained pipeline steel base metal and weld simulated heat affected zone specimens. The level of plastic pre-strain was 0-3%. The effective diffusion coefficient decreased with higher pre-strain. At higher pre-strain levels the effect of plastic deformation on hydrogen diffusion is dominating the influence of microstructure. Sub-surface hydrogen concentration was found to be unaffected by plastic strain. The calculated number of traps was clearly higher than results available for alpha ferrite in literature.

Kategori

Vitenskapelig foredrag

Språk

Engelsk

Forfatter(e)

Institusjon(er)

  • SINTEF Industri / Materialer og nanoteknologi
  • Norges teknisk-naturvitenskapelige universitet

Presentert på

ISOPE 2012

Sted

Rhodos

Dato

17.06.2012 - 22.06.2012

Arrangør

The International Society of Offshore and Polar Engineers

År

2012

Vis denne publikasjonen hos Cristin