Til hovedinnhold
Norsk English

Liquid insulation of IGBT modules: Long term chemical compatibility and high voltage endurance testing

Sammendrag

To facilitate operation of power electronics for subsea operation at ambient pressure components have to be submerged in a liquid. Equipment and schemes for testing of long term properties have been developed. Several techniques were used to investigate compatibility between a silicone gel and various insulation fluids. Equipment for electric endurance testing of power electronic components at dc stress under controlled temperature and humidity was developed. Performance of high voltage diodes covered with various insulation liquids, coatings and gel covering were studied.

Kategori

Vitenskapelig Kapittel/Artikkel/Konferanseartikkel

Oppdragsgiver

  • Research Council of Norway (RCN) / 215584

Språk

Engelsk

Institusjon(er)

  • SINTEF Energi AS / Elkraftteknologi
  • SINTEF Energi AS / Energisystemer
  • SINTEF Industri / Bioteknologi og nanomedisin

År

2016

Forlag

IEEE conference proceedings

Bok

Proceedings of the 2016 IEEE International Conference on Dielectrics, 3-7 July 2016, University of Montpellier, France : ICD 2016

ISBN

978-1-5090-2804-7

Vis denne publikasjonen hos Cristin