Determination of space behind frost insulation walls in tunnels using Ground Penetrating Radar. Hovettunnelen

Sammendrag

Hovettunnelen is located on E18 between Porsgrunn and Brevik.It has been inspected using Ground Penetrating Radar to determine the distance between the inside of the protective wall and the rock surface.   The measurements worked well and it was possible to identify the distance that will be useful to choose location for inspection hatches.

Kategori

Rapport

Språk

Engelsk

Forfatter(e)

  • Anne Lalagüe
  • Inge Hoff

Institusjon(er)

  • SINTEF Community / Infrastruktur

År

2009

Forlag

SINTEF rapport

Hefte nr.

SBF IN A09002

Vis denne publikasjonen hos Cristin