Analysis of the trilateral flash cycle and the partially evaporating cycle for power production from low temperature heat sources

Sammendrag

The Trilateral Flash Cycle (TFC) and the Partially Evaporating Cycle (PEC) have been analyzed and compared to the Organic Rankine Cycle (ORC). Three cases have been investigated. Case I uses air at 100 °C, Case II air at 150 °C and Case III air at 200 °C as the heat source. Water at 20 °C is used as the heat sink for all cases. The cycles are optimized for maximum net power production with eight different working fluids, R123, R134a, R245fa, R1234ze, butane, pentane, isopentane and propane. Detailed heat exchanger models to calculate the pressure drops and heat transfer coefficients are included in the model.
The results show that the TFC has the lowest power production for all cases, and the total system size is estimated to be larger for the TFC compared to the other cycles. The PEC doesn’t show any advantage over the ORC for the cases analyzed here.

Kategori

Vitenskapelig Kapittel/Artikkel/Konferanseartikkel

Språk

Engelsk

Forfatter(e)

  • Stian Trædal
  • Daniel Rohde
  • Trygve Magne Eikevik

Institusjon(er)

  • Norges teknisk-naturvitenskapelige universitet
  • SINTEF Energi AS

År

2014

Forlag

International Institute of Refrigeration

Bok

Proceedings of the 11th IIR-Gustav Lorentzen Conference on Natural Refrigerants GL2014

Hefte nr.

2014-3

ISBN

978-2-36215-004-3

Vis denne publikasjonen hos Cristin