Til hovedinnhold
Norsk English

Perceiving haptic feedback in virtual reality simulators

Sammendrag

Background

To improve patient safety, training of psychomotor laparoscopic skills is often done on virtual reality (VR) simulators outside the operating room. Haptic sensations have been found to influence psychomotor performance in laparoscopy. The emulation of haptic feedback is thus an important aspect of VR simulation. Some VR simulators try to simulate these sensations with handles equipped with haptic feedback. We conducted a survey on how laparoscopic surgeons perceive handles with and without haptic feedback.

Methods

Surgeons with different levels of experience in laparoscopy were asked to test two handles: Xitact IHP with haptic feedback and Xitact ITP without haptic feedback (Mentice AB, Gothenburg, Sweden), connected to the LapSim (Surgical Science AB, Sweden) VR simulator. They performed two tasks on the simulator before answering 12 questions regarding the two handles. The surgeons were not informed about the differences in the handles.

Results

A total of 85 % of the 20 surgeons who participated in the survey claimed that it is important that handles with haptic feedback feel realistic. Ninety percent of the surgeons preferred the handles without haptic feedback. The friction in the handles with haptic feedback was perceived to be as in reality (5 %) or too high (95 %). Regarding the handles without haptic feedback, the friction was perceived as in reality (45 %), too low (50 %), or too high (5 %). A total of 85 % of the surgeons thought that the handle with haptic feedback attempts to simulate the resistance offered by tissue to deformation. Ten percent thought that the handle succeeds in doing so.

Conclusions

The surveyed surgeons believe that haptic feedback is an important feature on VR simulators; however, they preferred the handles without haptic feedback because they perceived the handles with haptic feedback to add additional friction, making them unrealistic and not mechanically transparent.

Kategori

Vitenskapelig artikkel

Oppdragsgiver

  • Liaison Committee between the Central Norway Regional health Authority (RHA) and the Norwegian University of Science and Technology (NTNU) / 46056723

Språk

Engelsk

Forfatter(e)

Institusjon(er)

  • SINTEF Digital / Helse
  • St. Olavs Hospital HF
  • Norges teknisk-naturvitenskapelige universitet

År

2013

Publisert i

Surgical Endoscopy

ISSN

0930-2794

Forlag

Springer

Årgang

27

Hefte nr.

7

Side(r)

2391 - 2397

Vis denne publikasjonen hos Cristin