Dividing-Wall Column for Fractionation of Natural Gas Liquids in Floating Liquefied Natural Gas Plants

Sammendrag

The development of floating liquefied natural gas (FLNG) plants has resulted in a focus on reducing the weight and size of the topside processing facilities for these units. The conventional fractionation of natural gas liquids (NGL) in LNG plants implies a direct sequence of three or more conventional distillation columns requiring different levels of refrigeration. The results of a feasibility study are described, indicating that a packed three-product dividing-wall column (DWC) could replace conventional de-ethanizer and depropanizer columns. This could provide significant energy, hardware, weight, and footprint benefits, but, very likely, at the expense of an unaffordable cold utilities demand.

Kategori

Vitenskapelig artikkel

Språk

Engelsk

Forfatter(e)

Institusjon(er)

  • SINTEF Digital / Mathematics and Cybernetics
  • Sveučilište u Zagrebu
  • Equinor
  • Technische Universiteit Delft
  • Norges teknisk-naturvitenskapelige universitet

År

2016

Publisert i

Chemical Engineering & Technology

ISSN

0930-7516

Årgang

39

Hefte nr.

12

Side(r)

2348 - 2354